Comparative Analysis of the Effect of Natural and Mechanical Ventilation Systems on Indoor Radon Concentration in Offices within a Tertiary Institution in Southwestern Nigeria
Abstract
Radon is a colourless, odourless, tasteless radioactive gas that build up unnoticed
within interior spaces, particularly in poorly ventilated rooms. Radon stands as a
notable inAkpofureAdoor air contaminant and the second leading cause of lung
cancer after tobacco smoking. The aim of this study was to carry out a comparative
analysis of the effect of natural and artificial ventilation systems on indoor radon
concentration in offices within LAUTECH Ogbomoso. Indoor radon
concentration was measured using the RAD7 Radon Detector for six ventilation
conditions comprising three natural ventilation conditions (windows open only,
doors open only, and both windows and doors open) and three artificial ventilation
conditions (fans only, air conditioners only, and both fans and air conditioners).
The Annual Effective Dose Equivalent (AEDE) and Excess Lifetime Cancer Risk
(ELCR) were estimated from the measured radon concentrations. For natural
ventilation, the combined opening of windows and doors generally produced lower
indoor radon concentrations (4.879 – 11.062 Bq m⁻³) than opening windows only
(5.868 – 13.176 Bq m⁻³) or doors only (7.804 – 19.063 Bq m⁻³). For artificial
ventilation, offices utilizing fans recorded the lowest radon concentrations (5.285
– 7.554 Bq m⁻³), followed by combined fan-and-air-conditioner use (9.696 – 13.596
Bq m⁻³), while air-conditioner-only offices recorded the highest concentrations
(7.790 – 15.849 Bq m⁻³). One-way ANOVA confirmed that ventilation condition
significantly influenced indoor radon concentration for both natural ventilation (F
= 6.071, p = 0.007) and artificial ventilation (F = 42.360, p = 1.3 × 10⁻⁸).
Nevertheless, all measured indoor radon concentrations, AEDE values, and ELCR
values remained below the reference limits recommended by the World Health
Organization (WHO), the International Commission on Radiological Protection
(ICRP), and the United States Environmental Protection Agency (EPA). The study
established that adequate ventilation is an effective means of reducing indoor
radon accumulation and improving indoor environmental quality in office
buildings. This research contributes to the achievement of Sustainable
Development Goal 3 (SDG3) of good health and well-being.